a47e0aed3e
Phase 1 of full English translation: - generate_doorstop_items.py: all 55 items (SG/SYS/SWE/SA/SWA) rewritten in English - generate_landing_page.py: full UI labels, KPI cards, section headings in English - traceability.py: docstring, error messages, HTML headers in English - generate_test_report.py: report content + table headers in English - All 55 markdown items in safety/sg/, reqs/, arch/ regenerated in English Still to come: - demo-epb filled Word docs (PID, plans, safety, manuals, audit artefacts) - Code comments + test names + CI workflow step names - README + dev-process repo templates
15 lines
348 B
Markdown
15 lines
348 B
Markdown
---
|
|
active: true
|
|
derived: false
|
|
header: 'HMI status display'
|
|
level: 1.10
|
|
normative: true
|
|
reviewed: null
|
|
links: []
|
|
asil: QM
|
|
---
|
|
|
|
# SYS-010: HMI status display
|
|
|
|
The EPB status must be signalled to the driver: LED on the switch (on = applied, off = released, blinking = error) and a text in the instrument cluster via CAN bus (frame ID 0x3A0, 50 Hz).
|