a47e0aed3e
Phase 1 of full English translation: - generate_doorstop_items.py: all 55 items (SG/SYS/SWE/SA/SWA) rewritten in English - generate_landing_page.py: full UI labels, KPI cards, section headings in English - traceability.py: docstring, error messages, HTML headers in English - generate_test_report.py: report content + table headers in English - All 55 markdown items in safety/sg/, reqs/, arch/ regenerated in English Still to come: - demo-epb filled Word docs (PID, plans, safety, manuals, audit artefacts) - Code comments + test names + CI workflow step names - README + dev-process repo templates
363 B
363 B
active, derived, header, level, normative, reviewed, links, asil
| active | derived | header | level | normative | reviewed | links | asil | |
|---|---|---|---|---|---|---|---|---|
| true | false | Actuator current monitoring | 1.7 | true | null |
|
B |
SYS-007: Actuator current monitoring
The system must monitor the motor current of each actuator at at least 1 kHz and, on exceeding 8 A for more than 100 ms, shut down the actuator and set a DTC. Safety goal: SG-003.