--- active: true derived: false header: 'CAN-Status-Frame' level: 1.21 normative: true reviewed: null links: - SYS-010 asil: QM --- # SWE-021: CAN-Status-Frame Status-Frame 0x3A0 mit 50 Hz: Byte 0 = Status (0=Released, 1=Applied, 2=Applying, 3=Releasing, 0xFF=Error), Byte 1-2 = Klemmkraft links, Byte 3-4 = Klemmkraft rechts.